Page 50 - Signalite2023 ENG
P. 50

50 |
3.1 	 Connected systems
3.1.A. FOR SIMPLE DISPLAYS
The connected board can be used in many existing products and for different functionalities. It is also
configurable remotely with a display of its operating status via a supervision site accessible for each customer
with a username and password.
3.1.A1 SYNCHRONISED FLASHES
Single Flash, Double Flash, Stationary.
APPLICATIONS:
¡ Light display (LED signs, R1 Light, LED Light etc.).
¡ Running ones (configurable running).
¡ Control board for synchronised running ones via 8-output board.
¡ Synchronised dynamic panels.
3.1.A2 CLOCKS
Operation in Flash Mode but while following a defined schedule.
APPLICATIONS:
¡ Light display (school hours, holidays, daily etc.).
¡ Relay.
3.1.A3 REMOTE CONTROLS
Enables, via a radar for example, the activation of a sign located further away.
APPLICATIONS:
¡ Traffic jam.
¡ Transmitter/Receiver.
FEATURES:
› Input/output voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-24VDC
› Standby current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1mA
› Maximum current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.5A
› Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100W max
› Number of outputs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
› Number of synchronised lights: . . . . . . . . . . . . . . . . . . . . unlimited
› Clock Principle . . . . . . . . . . . . . . . . . . . . . . synchronous millisecond
› Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . integrated
› Web access  . . . . . . . . . . . . . . . . . . . . . . . . . . . Any recent navigator
Connected to the Cloud
Road Protection